Solar street lights, floodlights and off-grid lighting for Morocco

Compliance, standards and test reports

IEC / EN safety and performance standards, IP and IK ratings, battery transport and Moroccan requirements (NM standards, Cم marking): the frameworks our luminaires are designed and documented against.

This page gathers the documents LALOGO can attach to a consultation or a tender file in Morocco: PDF datasheets with the 4 numbers (LED W, lm, Wp, Wh), the IEC 60598 family references our luminaires are designed on, the declaration of conformity for the Moroccan Cم marking (Law 24-09, Orders 2573-14 and 2574-14) and IES/LDT photometric files on request.

The NM 06.8.001 file — the Moroccan standard 'Solar LED street lights for public lighting – General requirements' (IMANOR, 2024) — is in progress; we write 'compliant' nowhere until the corresponding test (16 h at ≥ 40 % flux at 25 °C, ≥ 130 lm/W) is reported. IK, L70, wind rating and salt-spray hours are given model by model on request. LALOGO warranty: see conditions.

Luminaire safety and performance

The IEC / EN references that give presumption of conformity for the Cم marking (Orders 2573-14 and 2574-14) and on which NM 06.8.001 relies; test reports supplied on request for the selected model.

IEC 60598-1 Luminaires – General requirements and tests IEC · adopted in Morocco as NM IEC 60598-1 (NM 06.7.080) Electrical, mechanical and thermal safety of every LALOGO luminaire; basis of the low-voltage declaration of conformity (Order 2573-14). Test report on request.
IEC 60598-2-3 Road and street lighting luminaires IEC · NM EN 60598-2-3 (NM 06.7.083) Particular requirements for all-in-one street lights, split kits and heads (LS-A, LS-S, LS-H series); required by NM 06.8.001 §5.1. Floodlights fall under part 2-5, garden lighting under part 2-4.
IEC 62717 LED modules – Performance requirements IEC · NM IEC 62717 (with NM EN 62031 for safety) Flux, lumen maintenance and efficacy of the 3030 / 5054 SMD LED modules (180–220 lm/W); NM 06.8.001 requires luminaire efficacy ≥ 130 lm/W per NM IEC 62722-2-1.
IEC 62471 Photobiological safety of lamps and luminaires IEC · NM EN 62471 Blue-light and UV risk grouping of the LED sources; low-voltage presumption-of-conformity standard cited in the IMANOR public-lighting guide.
EN 55015 / IEC 61547 Electromagnetic compatibility: emission and immunity CENELEC / IEC · NM EN 55015 and NM IEC 61547 Radio-frequency disturbance and immunity of the MPPT controllers and LED drivers; basis of the EMC declaration of conformity (Order 2574-14). Test report on request.

Protection and environment

IP / IK ratings, corrosion resistance and temperature range: NM 06.8.001 leaves IP and IK “specified by the client” (§7); LALOGO recommends IP66 / IK08 on the coast and IP65 / IK08 inland.

IEC 60529 IP65 / IP66 ingress protection IEC · NM EN 60529 IP65 as standard on street lights, heads, wall lights, bollards and the camera street light; IP66 on the LS-F100 / LS-F200 floodlights and on the coastal version of the street lights. Test report on request.
IEC 62262 IK08 impact resistance IEC · NM EN 62262 Target level for the die-cast aluminium housings and diffusers; value to write into the specification together with the IP rating. Test report on request for the selected model.
ISO 9227 Neutral salt-spray test – coastal version ISO · laboratory report on request IP66 coastal version with marine-grade coating for ISO 9223 class C4–C5 sites: seafront, ports, Mohammedia, El Jadida. Recommended for a coastal tender specification: ≥ 1,000 h (commercial practice, not a Moroccan requirement); 500 h is usual inland. Test duration for our models available on request.
−20 °C … +65 °C Operating temperature range LALOGO specification (datasheet of each model) Range validated for 45 °C summers and freezing Atlas nights; the BMS protects the LiFePO4 battery outside the range. A sealed housing in the sun exceeds the air temperature: hence night-time dimming and, on the hottest sites, the battery relocated to the pole base.

Batteries and transport

Documents required by shipping lines, airlines and the customs broker for any lithium battery; delivered with every shipment.

UN 38.3 Transport of lithium batteries UN Manual of Tests and Criteria · cell manufacturer's test report Altitude, thermal, vibration, shock, short-circuit and overcharge tests for the 3.2 V and 12.8 V LiFePO4 packs; report attached to the shipping documents.
IEC 62133-2 Safety of lithium secondary cells – LiFePO4 IEC · NM CEI 62133 (Orders 2573-14 / 2574-14) Standard retained by NM 06.8.001 §5.4 for Li-ion and LiFePO4 batteries, with a service life ≥ 5 years and a 16 h autonomy test at ≥ 40 % flux at 25 °C. Report on request.
MSDS Safety data sheet (MSDS / SDS) Cell manufacturer · LALOGO document per battery reference Composition, handling, storage and emergency measures for each battery reference; attached to the dangerous-goods declaration.

Moroccan requirements

What a commune, AREP or SRM specification asks for: the NM solar street light standard, the Cم marking and the NM EN 13201 photometric proof.

NM 06.8.001 Solar LED street lights for public lighting – General requirements IMANOR · committee CN 033 · file in progress Our datasheets address the draft standard's requirements (EP 52/2024): NM EN 13201 class, ≥ 130 lm/W, PV module ≥ 3 m above ground, weather-adaptive dimming, battery 16 h at 40 %, marking and Arabic manual. Status: file in progress; no “compliant” claim before the test report.
Loi 24-09 · arrêtés 2573-14 & 2574-14 Cم (CMIM) marking and declaration of conformity Ministry of Industry and Trade (MCINET) · IMANOR Mandatory marking for luminaires (low voltage and EMC), affixed on the product; LALOGO declaration of conformity issued per model on the basis of NM IEC 60598-1, NM EN 60598-2-x, NM EN 55015 and NM IEC 61547. IMANOR's NM mark remains voluntary.
NM EN 13201 IES / LDT photometric files for NM EN 13201 calculations LALOGO files per model · on request 70° × 140° asymmetric distribution of the LS-A, LS-S and LS-H series to verify the target class in DIALux (P3–P4 residential, M6 / P4–P5 douar, C4–C5 junction, indicative selection); both nomenclatures (2003 ME/CE/S and 2015 M/C/P) are supplied.
EN ↔ NM EN / IEC ↔ NM correspondence table LALOGO document · on request For every standard cited in our test reports, the equivalent homologated Moroccan standard (NM IEC 60598-1, NM EN 60598-2-3, NM EN 60529, NM EN 62262, NM CEI 62133, NM EN 55015, NM IEC 61547…), so the committee can check the reference-to-NM-standards requirement of Law 12-06 art. 35 and Decree 2-22-431 art. 5.

Manufacturing

Our ISO-certified manufacturing base in South China builds to LALOGO specifications; routine checks and type tests are described on the Manufacturing page.

ISO 9001 Quality management system of the manufacturing base Accredited certification body · certificate on request Batch traceability, incoming inspection of LiFePO4 cells and LED modules, routine tests (sealing, voltage, switch-on, programming) on every luminaire before shipment.

Test reports and declarations of conformity are issued for LALOGO products and can be provided to buyers and tender committees on request.

Send us your road, site or tender specification — get a technical offer within 24 hours

Tell us the road length, pole spacing, lighting class or simply the number of points and the city. Our engineers will propose the right model, autonomy calculation, price and delivery time to Morocco.

Last updated: 23 September 2026