IEC / EN safety and performance standards, IP and IK ratings, battery transport and Moroccan requirements (NM standards, Cم marking): the frameworks our luminaires are designed and documented against.
This page gathers the documents LALOGO can attach to a consultation or a tender file in Morocco: PDF datasheets with the 4 numbers (LED W, lm, Wp, Wh), the IEC 60598 family references our luminaires are designed on, the declaration of conformity for the Moroccan Cم marking (Law 24-09, Orders 2573-14 and 2574-14) and IES/LDT photometric files on request.
The NM 06.8.001 file — the Moroccan standard 'Solar LED street lights for public lighting – General requirements' (IMANOR, 2024) — is in progress; we write 'compliant' nowhere until the corresponding test (16 h at ≥ 40 % flux at 25 °C, ≥ 130 lm/W) is reported. IK, L70, wind rating and salt-spray hours are given model by model on request. LALOGO warranty: see conditions.
Luminaire safety and performance
The IEC / EN references that give presumption of conformity for the Cم marking (Orders 2573-14 and 2574-14) and on which NM 06.8.001 relies; test reports supplied on request for the selected model.
IEC 60598-1Luminaires – General requirements and testsIEC · adopted in Morocco as NM IEC 60598-1 (NM 06.7.080)Electrical, mechanical and thermal safety of every LALOGO luminaire; basis of the low-voltage declaration of conformity (Order 2573-14). Test report on request.
IEC 60598-2-3Road and street lighting luminairesIEC · NM EN 60598-2-3 (NM 06.7.083)Particular requirements for all-in-one street lights, split kits and heads (LS-A, LS-S, LS-H series); required by NM 06.8.001 §5.1. Floodlights fall under part 2-5, garden lighting under part 2-4.
IEC 62717LED modules – Performance requirementsIEC · NM IEC 62717 (with NM EN 62031 for safety)Flux, lumen maintenance and efficacy of the 3030 / 5054 SMD LED modules (180–220 lm/W); NM 06.8.001 requires luminaire efficacy ≥ 130 lm/W per NM IEC 62722-2-1.
IEC 62471Photobiological safety of lamps and luminairesIEC · NM EN 62471Blue-light and UV risk grouping of the LED sources; low-voltage presumption-of-conformity standard cited in the IMANOR public-lighting guide.
EN 55015 / IEC 61547Electromagnetic compatibility: emission and immunityCENELEC / IEC · NM EN 55015 and NM IEC 61547Radio-frequency disturbance and immunity of the MPPT controllers and LED drivers; basis of the EMC declaration of conformity (Order 2574-14). Test report on request.
Protection and environment
IP / IK ratings, corrosion resistance and temperature range: NM 06.8.001 leaves IP and IK “specified by the client” (§7); LALOGO recommends IP66 / IK08 on the coast and IP65 / IK08 inland.
IEC 60529IP65 / IP66 ingress protectionIEC · NM EN 60529IP65 as standard on street lights, heads, wall lights, bollards and the camera street light; IP66 on the LS-F100 / LS-F200 floodlights and on the coastal version of the street lights. Test report on request.
IEC 62262IK08 impact resistanceIEC · NM EN 62262Target level for the die-cast aluminium housings and diffusers; value to write into the specification together with the IP rating. Test report on request for the selected model.
ISO 9227Neutral salt-spray test – coastal versionISO · laboratory report on requestIP66 coastal version with marine-grade coating for ISO 9223 class C4–C5 sites: seafront, ports, Mohammedia, El Jadida. Recommended for a coastal tender specification: ≥ 1,000 h (commercial practice, not a Moroccan requirement); 500 h is usual inland. Test duration for our models available on request.
−20 °C … +65 °COperating temperature rangeLALOGO specification (datasheet of each model)Range validated for 45 °C summers and freezing Atlas nights; the BMS protects the LiFePO4 battery outside the range. A sealed housing in the sun exceeds the air temperature: hence night-time dimming and, on the hottest sites, the battery relocated to the pole base.
Batteries and transport
Documents required by shipping lines, airlines and the customs broker for any lithium battery; delivered with every shipment.
UN 38.3Transport of lithium batteriesUN Manual of Tests and Criteria · cell manufacturer's test reportAltitude, thermal, vibration, shock, short-circuit and overcharge tests for the 3.2 V and 12.8 V LiFePO4 packs; report attached to the shipping documents.
IEC 62133-2Safety of lithium secondary cells – LiFePO4IEC · NM CEI 62133 (Orders 2573-14 / 2574-14)Standard retained by NM 06.8.001 §5.4 for Li-ion and LiFePO4 batteries, with a service life ≥ 5 years and a 16 h autonomy test at ≥ 40 % flux at 25 °C. Report on request.
MSDSSafety data sheet (MSDS / SDS)Cell manufacturer · LALOGO document per battery referenceComposition, handling, storage and emergency measures for each battery reference; attached to the dangerous-goods declaration.
Moroccan requirements
What a commune, AREP or SRM specification asks for: the NM solar street light standard, the Cم marking and the NM EN 13201 photometric proof.
NM 06.8.001Solar LED street lights for public lighting – General requirementsIMANOR · committee CN 033 · file in progressOur datasheets address the draft standard's requirements (EP 52/2024): NM EN 13201 class, ≥ 130 lm/W, PV module ≥ 3 m above ground, weather-adaptive dimming, battery 16 h at 40 %, marking and Arabic manual. Status: file in progress; no “compliant” claim before the test report.
Loi 24-09 · arrêtés 2573-14 & 2574-14Cم (CMIM) marking and declaration of conformityMinistry of Industry and Trade (MCINET) · IMANORMandatory marking for luminaires (low voltage and EMC), affixed on the product; LALOGO declaration of conformity issued per model on the basis of NM IEC 60598-1, NM EN 60598-2-x, NM EN 55015 and NM IEC 61547. IMANOR's NM mark remains voluntary.
NM EN 13201IES / LDT photometric files for NM EN 13201 calculationsLALOGO files per model · on request70° × 140° asymmetric distribution of the LS-A, LS-S and LS-H series to verify the target class in DIALux (P3–P4 residential, M6 / P4–P5 douar, C4–C5 junction, indicative selection); both nomenclatures (2003 ME/CE/S and 2015 M/C/P) are supplied.
EN ↔ NMEN / IEC ↔ NM correspondence tableLALOGO document · on requestFor every standard cited in our test reports, the equivalent homologated Moroccan standard (NM IEC 60598-1, NM EN 60598-2-3, NM EN 60529, NM EN 62262, NM CEI 62133, NM EN 55015, NM IEC 61547…), so the committee can check the reference-to-NM-standards requirement of Law 12-06 art. 35 and Decree 2-22-431 art. 5.
Manufacturing
Our ISO-certified manufacturing base in South China builds to LALOGO specifications; routine checks and type tests are described on the Manufacturing page.
ISO 9001Quality management system of the manufacturing baseAccredited certification body · certificate on requestBatch traceability, incoming inspection of LiFePO4 cells and LED modules, routine tests (sealing, voltage, switch-on, programming) on every luminaire before shipment.
Test reports and declarations of conformity are issued for LALOGO products and can be provided to buyers and tender committees on request.
Send us your road, site or tender specification — get a technical offer within 24 hours
Tell us the road length, pole spacing, lighting class or simply the number of points and the city. Our engineers will propose the right model, autonomy calculation, price and delivery time to Morocco.